学位论文 > 优秀研究生学位论文题录展示

家兔血清样本中苯二氮卓类药物(阿普唑仑,地西泮,艾司唑仑)的检测

作 者: MAGDI OMER
导 师: 张强
学 校: 长春理工大学
专 业: 生物医学工程
关键词: Detection Alprazolam Diazepam Estazolam High-Performance LiquidChromatography
分类号: R446.11
类 型: 硕士论文
年 份: 2013年
下 载: 1次
引 用: 0次
阅 读: 论文下载
 

内容摘要


It recently became benzodiazepine abuse a serious social problem in the world, and the Chromatographic applications in the pharmaceutical sector and drugs among the fastest in fields and science detection of toxins in the blood. Using a simple and convenient method by High-Performance Liquid Chromatography (HPLC) high-tech (Agilent technologies1200series) to detect abuse of benzodiazepines in biologic samples is necessary to predict and protect human health risks. It has developed many of the helpful methods for qualification and quantification of medically prescribed benzodiazepines, in addition to many analytical techniques to determine the quantities of isolation and benzodiazepines in biological samples has already been published; among them, each thin-layer chromatography (TLC) and immunoassay approach remain extremely useful for a first rapid screening. However, both techniques lack high specificity and in the case of immuno-analysis, it is no discrimination between parent’s benzodiazepines and metabolites, On the other hand, gas chromatography’s (GC) with flame-ionization (GC/FID) or mass spectrometric detection (GC/MS) are much more sensitive and specific, but they require complex equipment and privatization procedure. Otherwise, the GC process can decompose thermolabile benzodiazepines like oxazepam and chlorazepate; the above-mentioned reasons resulted in a still-increasing popularity of HPLC for screening and quantitation of benzodiazepines in bio samples. Especially it is considered one of the most widely used analytical tools in the biotech industry. In this current study, we review the psychological description of this methodology (Agilent1200HPLC). The analytical results have been grouped based on the type of analysis narcotic drugs of the benzodiazepine group, of Schedule IV according to the rankings. These drug is; Alprazolam, Diazepam, Estazolam. To aim to know the concentration values of these drugs in serum in the hours varying after a dose medication when users abuse, it was been used three rabbits for the experiments work. The drug were given to rabbits, each one separately and drug dose as follows;(alprazolam, diazepam and estazolam), was extracted biological samples (serum) from the blood of rabbits in different hours;(alprazolam:1h,2h,4h,8h,12h,24h),(diazepam:1h,2h,10h,24h,36h),(estazolam:1h,3h,8h,12h,24h) respectively.Basic calibration standard to prepare of reagent is (KH2PO4[8g]-K2HPO4.3H2O [2g]-H2O [1000ml]), and has melted all of drugs in a solution consisting of (HCL) and (H2O), added by1:1. Moreover, separated was conducted on a carbon column (15Cm)(4.6×150mm,5μm)(C18) stationary phase, and are used methanol (CH3OH) and distilled water (H2O), and the mobile phases are (PBS:CH3OH) at a flow rate was (1ml/min), and an angel is (λ=238nm). The chemical residues from the device during the experiments are (CH3CN),(H2O).It has been injected of samples are as follows; Alprazolam (10μl), Diazepam (5μl), Estazolam (6μl,8μl,5μl) in (1h,3h,8h,12h,24h) respectively. Moreover, injection volumes of three serum samples are (10,7, and5μl), directly in the column with a mobile phase (PBS:CH3OH), and used UV to detect for alprazolam (λ=254nm), diazepam (λ=254nm), and estazolam (λ=223nm).In the results, the minimum concentration of alprazolam in a serum sample equivalent was (0μg/L) at (24h), while the maximum concentrations was (404.45μg/L) at (2h) in detection. In addition, the minimum concentration of diazepam was (141μg/L) at (36h), while the maximum concentration was (584μg/L) at (2h). In addition, estazolam, the minimum concentration was (27.2μg/L) at (24h), while the maximum concentration was (71.8μg/L) at (3h). Each detection process is over in20minutes, and then showed the tables and curves.

全文目录


Abstract  5-7
Contents  7-9
Chapter one: Introduction  9-22
  1.1 Background  9-15
  1.2 Importance of Research for Previous Studies with Regard of Benzodiazepines  15
  1.3 The Legal Status of Benzodiazepine in the World  15-16
  1.4 The Uses of Benzodiazepine  16-17
  1.5 The Reasons Why People Abuse Benzodiazepine  17-18
  1.6 The Risks Associated of Benzodiazepine Abuse  18
  1.7 The Dangers of Benzodiazepine Abuse and Addiction  18-19
  1.8 The History and Development of HPLC  19-20
  1.9 Importance Detects of Benzodiazepines Abuse by (HPLC) Method presently in the World  20
  1.10 Motivation for Choosing this Study  20-22
Chapter two: Definitions  22-29
  2.1 Definition of Benzodiazepine  22
  2.2 Definition of Gamma-Aminobutyric Acid (GABA)  22-23
  2.3 Definition and Chemical Structure of Alprazolam  23-24
  2.4 Definition and Chemical Structure of Diazepam  24-25
  2.5 Definition and Chemical Structure of Estazolam  25-26
  2.6 Definition of High-Performance Liquid Chromatography (HPLC) Technique  26
  2.7 Explain the Theory of (HPLC) Technique  26-27
  2.8 Definition of Term, (Abuse)  27
  2.9 Benzodiazepine (Alprazolam, Diazepam, and Estazolam), Half-Life and Equivalent dose  27-29
Chapter three: The Agilent Technologies 1200 series (HPLC)  29-38
  3.1 The Device Components  29-33
    3.1.1 Performance Specifications  29-31
    3.1.2 Physical Specifications  31-33
  3.2 Material and Methods  33-34
  3.3 Preparing the Reagent Method  34-38
Chapter four: Detection of Alprazolam  38-48
  4.1 Experiment Materials  38
  4.2 The method of Experiment  38-39
  4.3 Results and Discussion  39-48
Chapter five: Detection of Diazepam  48-57
  5.1 Experiment Materials  48
  5.2 The Method of Experiment  48
  5.3 Results and Discussion  48-57
Chapter six: Detection of Estazolam  57-66
  6.1 Experiment Materials  57
  6.2 The Method of Experiments  57
  6.3 Results and Discussion  57-66
Chapter seven:Conclusion  66-67
References  67-70
Acknowledgement  70

相似论文

  1. 利用TaqMan实时荧光PCR技术检测两种植物病毒CMLV和PRMV的研究,R450
  2. 氧化钛系材料的合成及在传感器中的应用,TP212
  3. 数据挖掘在入侵检测中的应用,TP311.13
  4. 距离跟踪α-β-γ滤波器,TN713.1
  5. 新型高灵敏荧光试剂的合成及在高效液相色谱和电泳中的应用研究,TQ421.3
  6. 基于空间几何位置的产品可装配性分析,TH122
  7. 黑客入侵检测与预警系统设计,TP393.08
  8. 短波和Inmarsat-C组合电子邮件系统设计,TP393.098
  9. 星上带容错功能的计算机引导系统的研究和实现,V443.2
  10. 一种新型混合式安全入侵检测系统HSIDS的设计,TP393.08
  11. 基于支持向量机的入侵检测系统的研究,TP393.08
  12. 基于高分辨率颅脑CT体数据的病变自动检出方法研究,TP391.41
  13. Applications of Flow Injection Analysis with Chemiluminescence Detection,O657.3
  14. 绵羊多产性状的DNA分子标记及相关研究,S826.2
  15. 神经元电活动诱发的树突整合功能的可塑性及其时空特异性,Q42
  16. Mormyrid电感受叶颗粒细胞对传入纤维动作电位的调控和电突触在电鱼脑内的分布:形态学、电生理学、计算机建模和免疫细胞化学研究,Q42
  17. 纳米材料在环境检测中的应用,X830.2
  18. User Detection in MIMO-OFDM System for Multiple Accesses,TN919.3
  19. Optimization of the Mechanical Design of the Dual Axis Inertially Stabilized Platform for the Line of Sight Stabilization,TH122
  20. 红外信号探测与处理,TN911.7

中图分类: > 医药、卫生 > 临床医学 > 诊断学 > 实验室诊断 > 生物化学检验、临床检验 > 血液学检验
© 2012 www.xueweilunwen.com